Aqualisa Quartz Shower Not Working – How to Fix It

One of the most common reasons for a Aqualisa Quartz shower unit to suddenly stop working is an air lock in the system. If you’ve experienced a power cut or have had to drain your hot/cold water tanks recently then an air lock is likely to be the cause.

This issue is particularly common on older rural properties that have a gravity fed water/heating system (usually characterised by a cold water tank in the loft and a hot water cylinder in an airing cupboard).

The main symptom of an air lock is that when you turn the shower on no water comes out of the shower head. After trying a few times (turning the shower on and off )you may find that all of a sudden no lights appear on the control dial altogether. Also you might hear a loud whining/rushing sound from the shower. Water may come out of the shower head in splurts if at all.

Aqualisa Quartz Shower Fix

How to Fix An Air Lock In Your Electric Shower System

The good news is an air lock is relatively straightforward to fix. It should only take you a few minutes and won’t need any tools or plumbing skills.

The control unit may have to be reset if none of the lights are on and no water is coming from the shower head.  This is simply a case of locating the control unit (usually in the loft or the airing cupboard) and switching the power off for 30 seconds, then back on again.

Here’s a picture of the pump/control unit which in our case is located in the airing cupboard near the bathroom.

Aqualisa Pump/Control Unit

Before turning the shower unit back on remove the shower head from the hose and let the hose dangle to the floor. This will reduce the pressure required to get water back through the system to the absolute minimum.

Next simply turn the dial to the coldest setting then turn the shower on. Let it run for a few seconds and hopefully you’ll get some spluttering of water out of the hose. If not, turn the shower off, wait a few seconds and try again.

When you turn the shower on and assuming some water is coming out, try leaving it on for a few seconds longer each time before switching it off. You should notice the spluttering decrease and more water come out of the hose each time.

Once water is running constantly from the hose slowly turn the temperature up a little at a time. Hopefully now there will be enough pressure in the pipes to ‘pull’ the hot water through the system.

If the above doesn’t work simply try turning the dial to the hottest setting instead and work backwards to the cooler temperatures.

You might need to repeat the process a few times before the shower returns back to a normal flow rate on both the hot and cold.

If the above doesn’t work another thing you can try is the following:

  1. Isolate (turn off the power to) the control/processor box
  2. Turn off the cold water supply entering the processor unit
  3. Unscrew the cold inlet to the processor box – inside there is a small gauze/filter. Remove it and clear any debris in it
  4. Reattach the cold supply then the power to the unit



If you found this article useful and have saved yourself the call out fee from a plumber, why not consider making a small donation to the site via paypal. You can do this via the above paypal button. This helps out massively with covering the hosting/maintenance of this site. Many thanks in advance!